Skip links

Concrete Durability Test

Rapid Chloride Migration Test of Concrete
Test Method: NT BUILD 492

Global Lab offers the Rapid Chloride Migration test of Concrete, which is conducted in accordance with NABL standards. This test provides crucial information about the durability of concrete in chloride-rich environments, helping clients assess and mitigate the risk of corrosion in their structures. Our experienced and qualified team uses state-of-the-art equipment and up-to-date testing procedures to deliver accurate and reliable results, ensuring the safety and longevity of our clients' concrete assets.

Rapid Chloride Migration Test of Concrete

  1. Interpretation of Results:
  2. The RCM test provides an indication of the concrete's resistance to chloride ion penetration.
  3. A lower chloride migration coefficient signifies better resistance to chloride ingress.
  4. Benefits:
  5. The RCM test offers a rapid and quantitative assessment of concrete's resistance to chloride migration.
  6. It helps evaluate the durability of concrete structures exposed to chloride-rich environments.

Rapid Chloride Penetration Test
Test Method: ASTM C1202

The Rapid Chloride Penetration Test (RCPT) is a quick and widely used test to assess the chloride ion permeability of concrete. It measures the concrete's resistance to chloride penetration by subjecting a specimen to an electrical potential. Lower charge values or shallower penetration depths indicate better resistance. The RCPT is beneficial for evaluating concrete durability in chloride-rich environments. Trust Global Lab for reliable RCPT services, ensuring accurate results and informed decision-making.

  • Interpretation of Results:The RCPT provides an indication of the concrete's resistance to chloride ion penetration.
    Results are typically reported as the electrical charge passed or the chloride penetration depth.
  • Lower charge values or shallower penetration depths indicate better resistance to chloride ingress.
  • Benefits:
  • The RCPT is a rapid test that provides a quantitative assessment of concrete's resistance to chloride penetration.
  • It helps evaluate the durability of concrete in chloride-rich environments, such as coastal or de-icing salt exposure.

Concrete Depth of Water Penetration
Test Method: IS 516 Part 2 Sec

At Global Lab, we are dedicated to providing comprehensive testing services for construction materials. One crucial test we offer is the Concrete Depth of Water Penetration test, which evaluates a concrete sample's ability to resist water penetration. This test helps assess the durability and performance of concrete structures in various environments.

  1. Sample Preparation: Select representative concrete samples and shape them into cylinders or cubes.
  2. Drying: Remove surface moisture by subjecting the samples to a specific temperature in an oven.
  3. Water Submersion: Immerse the dried samples in water, maintaining a water level above the top surface.
  4. Water Absorption: Remove samples from water, wipe off excess surface water, and weigh them in the saturated surface-dry (SSD) condition.
  5. Core Extraction: Cut or core a section of the samples to expose a cross-section.
  6. Depth Measurement: Measure the depth of water penetration visually or using techniques like dye penetration or electrical resistivity.

Concrete Initial Surface Absorption Test
Test Method: BS 1881 : Part 208

At Global Lab, we offer a comprehensive range of testing services for construction materials. One key test we specialize in is the Initial Surface Absorption Test (ISAT) for concrete. This test enables us to evaluate the surface permeability of concrete and assess its ability to resist the penetration of liquids, such as water or chemicals.

  1. Purpose: Assess concrete's permeability and resistance to liquid ingress.
  2. Test Specimens: Carefully prepared concrete specimens representing the material being tested.
  3. Test Setup: Concrete specimen placed on a raised platform, water poured on the surface.
  4. Measurement: Precise measurement of water absorption rate over time.
  5. Calculation: Determination of initial surface absorption rate.
  6. Interpretation: Insights into concrete's surface permeability and resistance.
  7. Applications: Quality control, mix design selection, evaluating surface treatments.
  8. Global Lab Expertise: State-of-the-art facilities, experienced professionals, adherence to international guidelines for accurate results.

Concrete Drying Shrinkage Test
Test Method: ASTM 157

The Concrete Drying Shrinkage Test is conducted to measure the extent of shrinkage that occurs in concrete as it dries and loses moisture. This test helps assess the potential for cracking and deformation in concrete structures due to drying shrinkage.

  1. Test Specimens: Specially prepared concrete specimens resembling the actual material.
  2. Initial Measurement: Precise measurement of specimen dimensions before drying.
  3. Drying Conditions: Specimens exposed to controlled low humidity or specific drying conditions.
  4. Dimensional Changes: Regular measurements track changes in length, width, and thickness.
  5. Calculation: Percentage of drying shrinkage calculated based on dimensional changes.
  6. Significance: Understand concrete behavior, predict cracking, and design appropriate reinforcement and control joints.
  7. Test Standards: Follow guidelines such as ASTM C157, ASTM C596, or EN 13687-2.

Modulus of Elasticity of Concrete
Test Method: ASTM C 469

The modulus of elasticity is a fundamental property that measures the stiffness and flexibility of materials. In the context of concrete, it refers to the ability of the material to deform elastically when subjected to external loads

  1. Measurement: Determined through specialised laboratory tests like static or dynamic modulus of elasticity test.
  2. Factors Affecting Modulus: Influenced by concrete mix design, aggregate properties, curing conditions, and age of the concrete.
  3. Significance: Crucial for structural design & analysis, understanding concrete behavior, ensuring safety and performance.
  4. Relationship with Strength: Indirectly related to compressive strength, generally increasing as concrete strength increases.
  5. Limitations: Modulus of elasticity varies based on concrete type and age, subject to change over time due to creep and shrinkage.

Get a Free Quote

    Call us at

    98200 04115

    Mass Concrete Temperature Monitoring

    Mass concrete temperature monitoring is a crucial practice employed during the construction of large concrete structures, such as dams, bridges, and high-rise buildings. It involves the continuous measurement and recording of the internal temperature of the concrete mass to ensure proper curing and prevent thermal cracking.

    Mass Concrete Temperature Monitoring

    1. Purpose: Manage concrete heat, control temperature rise, and prevent cracking.
    2. Sensors: Strategically placed to capture accurate temperature data.
    3. Data Collection: Continuous recording of temperature readings.
    4. Analysis: Identify abnormal temperature rise and assess thermal behavior.
    5. Control Measures: Adjust concrete mix, use cooling techniques, and apply insulation.
    6. Schedule Adjustment: Optimize concrete placement timing and curing methods.
    7. Compliance: Meet construction codes and guidelines for durability.
    8. Expert Guidance: Experienced professionals ensure effective temperature monitoring.